2020 – IMR Balder FPSO Phase I & II
Client: Vår Energi
Vessel: Edda Freya/LDC Venturer
Period: June – July 2020
Task: DBSC Inspection GVI & CVI
Real Results:
Inadequate Access for ROV Inspection.
Challenge:
No inspection results from FPSO turret.
Solution:
LDC Dive spread mobilised onboard client IMR vessel. DBSC’s cleaned and visual inspection carried out (GVI & CVI). Due to poor cathodic protection several areas of concern were reported.
Outcome:
Follow up project to install new continuity cables, DBSC actuator ring locking system repaired, retrofit anodes designed by specialist sub-contractor installed. Fully restored local cathodic protection.